NeuroLog System

 

NL905-neurolog-system-digitimer

The NeuroLog System is a compact, versatile & modular instrument which can be used for intracellular recording, extracellular recording, transducer & multi-channel isolated amplification.  It can also be configured for pulse generation timing & electrical Stimulation, signal processing & conditioning.

The modular nature of the NeuroLog System means that in many cases researchers will use one system to monitor several parameters of interest simultaneously.  The NeuroLog System is now available with a choice of two cases/power supply units – 19″ rack mountable NL900D for up to 13 modules and the compact NL905 for up to 4 modules.

Not sure what modules you need for your application?  Please contact us to discuss your requirements or take a look at the application notes we provide.

For a complete overview of the NeuroLog System range and a selection of application notes please download our Neurolog System Brochure or visit the NeuroLog System Application Notes page.

 

 

These modules accept an analogue signal, which is converted into digital outputs. The NL601 has a digital counter which produces an analogue output proportional to the count, while the NL201 is an amplitude/window discriminator used for detection of neuronal action potentials (spikes), during electrophysiological recording.

NL601-pulse-generator-digitimerNL201-spike-trigger-digitimer

NL201 – Spike Trigger
NL601 – Pulse Integrator

NeuroLog System includes a range of amplifier modules designed for a variety of electrophysiological recording applications.  Our amplifiers  are suitable for intracellular, extracellular microelectrode and gross electrode recordings as well as isolated multi-channel EEG/EMG.  The range also includes bridge amplifiers for force and pressure measurements.

amplifier-modules

NL100AK – Differential Headstage
NL100RK – Stimulus Control Headstage
NL102G – Intracellular DC Preamplifier
NL104A – Extracellular AC Preamplifier
NL106 – AC/DC Amplifier
NL108A – Pressure Amplifier
NL109 – Bridge Amplifier
NL120S – Audio Amplifier
NL820A – Isolator
NL822 – Two Channel AC Preamplifier
NL844 – Four Channel AC Preamplifier

The NL202 AC Signal Delay is an analog signal delay unit utilizing a ‘bucket-brigade’ delay line, providing a low cost unit and almost continuous representation of the delayed signal. The NL254 calculates, using digital circuitry, the ‘instantaneous frequency’….

analogue-modules

NL254 – Ratemeter
NL506 – Analogue Switch
NL703 – EMG Integrator

The NL405 is a digitally controlled pulse duration generator and is used to produce precise pulses of adjustable duration with high accuracy and repeatability. This module combines many of the features of the discontinued NL401 Digital Width…

digital-modules

NL405 – Width/Delay
NL501 – Logic Gate
NL505 – Flip Flop
NL603 – Counter
NL730 – Pulse Shift

These modules provide the basic pulse generation mechanism within a NeuroLog System. When appropriately used, the NL301 Pulse Generator and NL304 Period Generator can initiate repetitive pulses/periods which can be used to synchronize external devices….

generator-modules

NL301 – Pulse Generator
NL304 – Period Generator
NL412 – Pulse Box

The NL800A Stimulus isolator is a compact source of constant current stimulation, however, it requires an input voltage (provided by the NL510 Pulse Buffer or NL512 Biphasic Buffer) to control the output pulse duration and amplitude.

stimulator-modules

NL510 – Pulse Buffer
NL512 – Biphasic Buffer
NL800A Constant Current Isolator

The NEW NL905 Compact Case & Power Supply unit provides researchers with a smaller alternative to the NL900D Case. The NL905 has space for up to 4 modules and is fully compatible with all existing NeuroLog modules.

NeuroLog-Case-&-Power-Supply

NL900D Neurolog System Case
NL905 Compact Neurolog System Case

The NL125/6 band-pass filter module employs two active sections to control the high and low pass characteristics. The low frequency cutoff point can be set continuously from 0.5Hz to 5kHz with a single turn potentiometer, in four switched ranges.

Filter-&-Conditioner-Modules

NL125/6 – Band-Pass Filter
NL134/5/6 – Four Channel Low Pass Filters
NL143 – Three Channel Difference Amplifier
NL144 – Four Channel High Pass Filter
NL530 – Signal Conditioner
NL540 – Inverting Attenuator (Alt. Gain)

To enable the user to make full use of the NeuroLog System, we make available a wide range of accessories – at least some will be required for each and every system. No accessory leads or connectors are supplied with the modules….

neurolog-accessory-kit

Accessory Kits
Adaptors & Adaptor Cables
Sockets (for cable mounting)
Sockets (for panel mounting)
Plugs (for cable mounting)
Extension Cables
Cables
Electrode Holders
Miscellaneous Items

The Neurolog System includes a range of transducers and accelerometers for making measurements of in vivo pressures, muscle force and limb acceleration or tremor. Disposable and re-useable pressure transducers….

Pressure-Transducers-&-Accelerometers

Pressure Transducers
Force Transducers
Accelerometers